Description
EMERGENSEAL Repair Kit Directions
Mixing
Thoroughly mix the two parts, supplied in pre-measured sachet packs until no streaks are seen. Apply to surface rapidly, pressing hard to achieve maximum wetting, then proceed with thickness desired. Mix no more product than can be applied in 5 minutes. When rebuilding structures, use layers of reinforcing cloth and apply product as thick as the parent substrate.
Ratio 2A:1B by volume 2A:1B by weight
Pot Life 5 minutes
Multi-layers
If building layers or pipe wrapping with reinforcing cloth, apply the coating within the recoat window. If this is not possible, allow the compound to cure, then create a mechanical profile by grit blasting, grinding or power tool sanding the surface before coating.
Application
Apply directly on to the prepared surface with the plastic applicator or spatula provided. Press down firmly to remove entrapped air, fill all cracks, and ensure maximum contact with the surface. Use can use reinforcement tape or mesh over holes and cracks. Fully machinable using conventional tools once cured.
Brush & Roller – Brush or roller can be used to smooth uncured surface with solvent if desired.
Cleanup – Use MEK or Acetone.
EMERGENSEAL Product Data
EMERGENSEAL Part A SDS
EMERGENSEAL Part B SDS
Reviews